Abstract:
Solar power tower is a dispatchable clean energy technology, but its performance will be affected by cloud covers during actual operation, resulting in continuous changes in the concentrated solar energy, which in turn leads to unstable energy output and safety problem of the receiver. At present, most researches focused on the thermalperformance of the heliostat field under uniform radiation attenuation or regular cloud cover shapes. The influence of real cloud covers on the thermal performance of the receiver and tube temperatures was scarce. In order to investigate the influence of real cloud cover on the focusing and heat transfer performance of the heliostats and the receiver, a numerical calculation model was developed. The model coupled the heliostat field and the receiver under real cloud shadows. The Crescent Dunes tower plant was used as the research prototype. The image of real cloud shadow was segmented and converted into a binary image, which was imported into the Python API program of the SolarPILOT software. So, the influence cloud shadow on the concentrated heat flux distribution of the receiver could be obtained. Then, a multi-physics coupled model was developed to obtain the thermal performance and temperature distribution of the receiver. By using a multiple sets of real cloud shapes, which had a shadow ratio ranging from 20% to 50%, the changes in the concentrated heat flux distribution, the molten salt flow rate, the tube wall temperature, and the film temperature were analyzed. The results indicate that the distribution of concentrated heat flux on the receiver was not only affected by the overall shadowed areas, but also affected by the shape of cloud shadows. Cloud shadows could easily cause the location change of the peak heat flux, resulting in a multimodal distribution of the heat flux. When the mass flow rate of molten salt in the circuit was small, the molten salt temperature might be higher than its thermal decomposition limit, and the film temperature might also be higher than the operating limit of 650 ℃, which causing a significant increase in the corrosion rate of the tube. So, the safe operation the receive was affected. To maintain the outlet temperature of the working fluid, the plant should reduce the mass flow rate under cloudy conditions, and there existed hot spots on the receiver. So, the convective and radiative heat losses of the receiver did not decrease proportionally with the decrease of the total incident energy, resulting in the thermal efficiency of the receiver lower than 85%. And the efficiency would fluctuate for different cloud shapes. The present research can provide theoretical and technical support for the safe operation of receiver under cloudy conditions.